HFCT传感器

HFCT Sensor

工 作 原 理:罗氏线圈
传感器类型:圆环可开合结构
工 作 频 带:1MHz-30HMz
传 输 阻 抗:>8Ω
防 护 等 级:IP68
信 号 接 口:N-50插座或者BNC接头可选
传感器内径:65mm、45mm可选
外      壳:金属外壳(满足盐雾96小时测试)
灵  敏  度:<5pC

    本公司自主研发的HFCT传感器为类圆环开合式设计,实现非侵入式安装检测方式,广泛适用于各种电力监控现场。传感器采用特殊处理金属外壳,可实现电力现场复杂电磁环境屏蔽抗干扰,还适用于全天候户外使用需求(可满足96H的盐雾测试),传感器接入后端的测量设备进行处理传输(包含滤波、检波、调理、数字化,识别、远传),以便对运行电力设备进行在线或者巡检监控。
     局部放电(PD)是由于用户电气高压绝缘系统的缺陷而发生的故障之一,用户需要局放测量来监控设备状况并避免故障。HFCT传感器设计采用罗哥夫斯基线圈(Rogowski Coil)原理,高频电流引起罗氏线圈磁场变化从而在线圈出线端生成感应电压。当高压电缆内部发生局部放电时,会产生高频脉冲电流信号,该信号通过电缆接头或终端处的接地线引入大地,在接地线上采用非侵入的方式安装HFCT传感器,可实现对电缆局部放电的状态检测。

       The HFCT sensor independently developed by our company is a ring like open and close design, which realizes the non-invasive installation and detection mode and is widely applicable to various power monitoring sites. The sensor adopts a specially processed metal shell, which can realize the shielding and anti-interference of the complex electromagnetic environment in the power field, and is also suitable for all-weather outdoor use (can meet the 96H salt fog test). The sensor is connected to the measuring equipment at the back end for processing and transmission (including filtering, wave detection, conditioning, digitization, identification, remote transmission), so as to conduct online or patrol inspection and monitoring of the operating power equipment.

     Partial discharge (PD) is one of the faults that occur due to the defects of the user’s electrical high-voltage insulation system. The user needs partial discharge measurement to monitor the equipment condition and avoid faults. The HFCT sensor is designed based on the principle of Rogowski Coil. High frequency current causes the magnetic field of Rogowski coil to change, thus generating induced voltage at the coil outlet. When partial discharge occurs inside the high-voltage cable, high-frequency pulse current signal will be generated. This signal is introduced to the ground through the cable connector or the grounding wire at the terminal. The HFCT sensor is installed on the grounding wire in a non-invasive way to detect the status of cable partial discharge.

电话:028-85543173   蜀ICP备2022021812号